• Article  

      Hemostasis Management in Pediatric Mechanical Circulatory Support 

      Seibel, K.; Berdat, Pascal; Boillat, Colette; Wagner, B.; Zachariou, Zacharias; Kessler, Ulf (2008)
      In a 9-year-old boy, bridging to transplantation was successful with an external biventricular device, the Berlin Heart Excor (Berlin Heart, Berlin, Germany), during a 7-month period. Main long-term complications consisted ...