dc.description.abstractAbstract: The aim of this study was to measure the relationship of image intensity with contrast agent concentration. In vitro experiments were performed with a flow phantom and a sulphur hexafluoride filled microbubble contrast agent (SonoVue) at different concentrations (0.004‰ to 4‰) covering the range commonly encountered in clinical practice. The concentration of microbubbles in the contrast agent solutions was confirmed optically. Images were collected with a diagnostic ultrasound system (iU22, Phillips Medical Systems, Bothell, WA, USA) and with a nonlinear imaging technique (power modulation) at low mechanical index (MI=0.05) to avoid bubble destruction. The mean intensity within a region of interest was measured to produce time-intensity curves from linearized (absolute scale) data. The relationship of linearized image intensity to contrast agent concentration was found to be linear up to 1‰ and reached a plateau at approximately 2‰. To operate in the linear range of the intensity-concentration relationship the contrast agent dose should be adjusted to avoid those high values in vivo and the highest dynamic range of the ultrasound system should be used to avoid unnecessary signal saturation. (E-mail: maverk@ucy.ac.cy). Copyright &y& Elsevier]en
dc.description.abstractCopyright of Ultrasound in Medicine & Biology is the property of Elsevier Science Publishing Company, Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)en
dc.sourceUltrasound in medicine & biologyen
dc.subjectNonlinear theoriesen
dc.subjectImaging systems in medicineen
dc.subjectDynamic rangeen
dc.subjectConcentrationen
dc.subjectUltrasound contrast agentsen
dc.subjectMicrobubblesen
dc.subjectUltrasonic imagingen
dc.subjectBackscatteringen
dc.subjectDosage of drugsen
dc.subjectImage analysisen
dc.subjectLinearized image intensityen
dc.titleInvestigation of the Relationship of Nonlinear Backscattered Ultrasound Intensity with Microbubble Concentration at Low MIen
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1016/j.ultrasmedbio.2009.09.011
dc.description.volume36
dc.description.startingpage306
dc.description.endingpage312
dc.author.facultyΠολυτεχνική Σχολή / Faculty of Engineering
dc.author.departmentΤμήμα Μηχανικών Μηχανολογίας και Κατασκευαστικής / Department of Mechanical and Manufacturing Engineering
dc.type.uhtypeArticleen
dc.contributor.orcidAverkiou, Michalakis A. [0000-0002-2485-3433]
dc.description.totalnumpages306-312
dc.gnosis.orcid0000-0002-2485-3433


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record