Immune monitoring in transplant patients treated with cyclosporine (Cy)
Ημερομηνία
1983Συγγραφέας
Kyriakides, George K.Flaa, C.
Olson, L.
Miller, Jody C.
Source
Transplantation proceedingsVolume
15Issue
3Pages
1933-1935Google Scholar check
Metadata
Εμφάνιση πλήρους εγγραφήςΕπιτομή
In the present study, correlation of cyclosporine dose with serum drug levels (radioimmunoassay), kidney function, and immunologic monitoring in transplant patients was made in an attempt to define the parameter(s) to be followed for the correct determination of the cyclosporine dose in each individual patient.