Show simple item record

dc.contributor.authorMavroudi, Maria C.en
dc.contributor.authorKapnissi‐Christodoulou, Constantina P.en
dc.creatorMavroudi, Maria C.en
dc.creatorKapnissi‐Christodoulou, Constantina P.en
dc.date.accessioned2019-11-21T06:21:24Z
dc.date.available2019-11-21T06:21:24Z
dc.date.issued2015
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/55840
dc.source.urihttps://nls.ldls.org.uk/welcome.html?ark:/81055/vdc_100026598164.0x00002c
dc.subjectElectrophoresisen
dc.titleCombined use of l‐alanine tert butyl ester lactate and trimethyl‐β‐cyclodextrin for the enantiomeric separations of 2‐arylpropionic acids nonsteroidal anti‐inflammatory drugsen
dc.typeinfo:eu-repo/semantics/article
dc.author.faculty002 Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences
dc.author.departmentΤμήμα Χημείας / Department of Chemistry
dc.type.uhtypeArticleen
dc.description.notes<p>ID: 1054en
dc.description.notesIn: Electrophoresis, Vol. 36, no. 19 ( 2015), p.2442-2450.en
dc.description.notesSummary: AbstractIn this study, a new CE method, employing a binary system of trimethyl‐β‐CD (TM‐β‐CD) and a chiral amino acid ester‐based ionic liquid (AAIL), was developed for the chiral separation of seven 2‐arylpropionic acid nonsteroidal anti‐inflammatory drugs (NSAIDs). In particular, the enantioseparation of ibuprofen, ketoprofen, carprofen, indoprofen, flurbiprofen, naproxen, and fenoprofen was improved significantly by supporting the BGE with the chiral AAIL l‐alanine tert butyl ester lactate (l‐AlaC4Lac). Parameters, such as concentrations of TM‐β‐CD and l‐AlaC4Lac, and buffer pH, were systematically examined in order to optimize the chiral separation of each NSAID. It was observed that the addition of the AAIL into the BGE improved both resolution and efficiency significantly. After optimization of separation conditions, baseline separation (Rs>1.5) of five of the analytes was achieved in less than 11 min, while the resolution of ibuprofen and flurbiprofen was approximately 1.2. The optimized enantioseparation conditions for all analytes involve a BGE of 5 mM sodium acetate/acetic acid (pH 5.0), an applied voltage of 30 kV, and a temperature of 20°C. In addition, the results obtained by computing the %‐RSD values of the EOF and the two enantiomer peaks, demonstrated excellent run‐to‐run, batch‐to‐batch, and day‐to‐day reproducibilities.</p>en
dc.contributor.orcidKapnissi‐Christodoulou, Constantina P. [0000-0003-3755-1052]
dc.gnosis.orcid0000-0003-3755-1052


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record