dc.description.abstractA systematic study of the indoor airborne radon concentration in the central part of the Nicosia district was conducted, using high-sensitivity active radon portable detectors of the type "RADIM3A". From a total of 108 measurements in 54 grids of 1 km 2 area each, the overall mean value is 20.6 ± 13.2 Bq m -3 (A.M. ± S.D.). That is almost twice less than the corresponding average worldwide value. The radon concentration levels in drinking water were also measured in 24 sites of the residential district, using the high-sensitivity radon detector of the type "RADIM3W". The mean value obtained from these measurements is 243.8 ± 224.8 mBq l -1, which is relatively low compared to the corresponding internationally accepted level. The associated annual effective dose rates to each measurement were also calculated and compared to the corresponding worldwide values. From the geographical coordinates of the measuring sites and the corresponding radon concentration values, the digital radon map of the central part of the Nicosia district was constructed for the first time, by means of the ArcMap software package. © 2012 Elsevier Ltd. All rights reserved.en
dc.sourceRadiation Measurementsen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84861927585&doi=10.1016%2fj.radmeas.2012.03.019&partnerID=40&md5=e268d9f2bf316a602353e0f555c327f2
dc.subjectCyprusen
dc.subjectRadonen
dc.subjectRadioactivityen
dc.subjectRadon concentrationsen
dc.subjectDetectorsen
dc.subjectEffective dose rateen
dc.subjectPortable active radon detectorsen
dc.subjectRadon detectorsen
dc.subjectArcMapen
dc.subjectGrid-wise radon mapen
dc.subjectRadon concentrationen
dc.titleSystematic grid-wise radon concentration measurements and first radon map in Cyprusen
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1016/j.radmeas.2012.03.019
dc.description.volume47
dc.description.issue6
dc.description.startingpage451
dc.description.endingpage460
dc.author.facultyΣχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences
dc.author.departmentΤμήμα Φυσικής / Department of Physics
dc.type.uhtypeArticleen
dc.description.notes<p>Cited By :1</p>en
dc.source.abbreviationRadiat.Meas.en
dc.contributor.orcidTsertos, Haralambos [0000-0001-5966-343X]
dc.gnosis.orcid0000-0001-5966-343X


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record