• Conference Object  

      An adaptive multiscale AM-FM texture analysis system with application to hysteroscopy imaging 

      Constantinou, Ioannis P.; Pattichis, Marios S.; Tanos, Vasilios; Neofytou, Marios S.; Pattichis, Constantinos S. (2012)
      The use of multiscale AM-FM analysis systems has been recently demonstrated in a variety of applications in medical image analysis. In all of these applications, a fixed filter-bank is used as a preprocessing step for ...
    • Conference Object  

      Classification and data mining for hysteroscopy imaging in gynaecology 

      Neofytou, Marios S.; Loizou, A.; Tanos, Vasilios; Pattichis, Marios S.; Pattichis, Constantinos S. (2008)
      The objective of this study was to develop a CAD system for the classification of hysteroscopy images of the endometrium (with suspicious areas of cancer), based on two data mining procedures, the C4.5 and the Hybrid ...
    • Article  

      Computer-aided diagnosis in hysteroscopic imaging 

      Neofytou, Marios S.; Tanos, Vasilios; Constantinou, Ioannis P.; Kyriacou, Efthyvoulos C.; Pattichis, Marios S.; Pattichis, Constantinos S. (2015)
      The paper presents the development of a computeraided diagnostic (CAD) system for the early detection of endometrial cancer. The proposed CAD system supports reproducibility through texture feature standardization, ...
    • Conference Object  

      An integrated CAD system facilitating the endometrial cancer diagnosis 

      Constantinou, Ioannis P.; Koumourou, C. A.; Neofytou, Marios S.; Tanos, Vasilios; Pattichis, Constantinos S.; Kyriacou, Efthyvoulos C. (2009)
      In this study we present an integrated system for supporting the diagnosis of endometrial cancer. The system consists of an electronic patient record that incoporates a hysteroscopy imaging CAD system for the early detection ...
    • Conference Object  

      Reliable hysteroscopy color imaging 

      Constantinou, Ioannis P.; Tanos, Vasilios; Neofytou, Marios S.; Pattichis, Constantinos S. (2010)
      The aim of this study was to investigate the reliability of two hysteroscopy cameras, the Circon IP 4 and Karl Storz HD, in relation to white balance, camera response over time, and color correction. Experimental results, ...
    • Conference Object  

      A simplified 2D real time navigation system for hysteroscopy imaging 

      Herakleous, I.; Constantinos, I. P.; Michael, E.; Neofytou, Marios S.; Pattichis, Constantinos S.; Tanos, Vasilios (2011)
      In this paper, a simplified 2D navigation system for hysteroscopy imaging was introduced. This system was evaluated in virtual endometrium models, and the position sensor measurement errors were very small and acceptable ...
    • Conference Object  

      Texture analysis of the endometrium during hysteroscopy: Preliminary results 

      Neophytou, Michael S.; Pattichis, Constantinos S.; Pattichis, Marios S.; Tanos, Vasilios; Kyriacou, Efthyvoulos C.; Pavlopoulos, Sotirios A.; Koutsouris, Demetrios Dionysios (2004)
      The objective of this study is to investigate the usefulness of texture analysis in the endometrium during hysteroscopy in endoscopic imaging of the uterine cavity. Endoscopy images from the endometrium from three subjects, ...