dc.description.abstractPurpose: This study recorded and analysed streak and motion artifacts in spiral CT examinations and evaluated the elimination and minimization of them by the use of segmental reconstruction with and without alterations of the initial examination protocol. Materials and methods: One hundred CT scans of the chest and 300 CT scans of the brain have been included in this study. All studies were performed by a helical CT scanner (Philips 5000 SR) with the standard protocol and were randomly selected due to the presence of either streak or motion artifacts. Segmental reconstruction was applied in all cases by the same experienced radiographer. Image evaluation was performed by two experienced radiologists using a scoring system for each artifact and a grading system for classifying post-processing images. Results: Among series of images that were evaluated after the application of segmental reconstruction, brain examinations demonstrated the following results: 10.9% of the cases showed no artifact improvement, 19.6% showed slight artifact improvement 31.5% showed moderate improvement and 38% showed significant improvement. The results of chest examinations were as follows: 27% of the cases showed no artifact improvement, 23% showed slight artifact improvement, 26% showed moderate improvement and 24% of showed significant improvement. Spatial reconstruction was useless in brain CT images when a patient moved during the entire scan and in chest CT images when streak and motion artifacts co-existed. Conclusions: Spatial reconstruction may improve the image quality in brain and chest CT examinations and thus may contribute to more diagnostic images. Elimination of motion artifacts is also suggested due to the limitation of intravenous contrast medium that can be administered per patient per day and in cases of non-cooperative patients. © 2009 Euro-med Congress for Radiographers.en
dc.language.isoengen
dc.sourceEuropean Journal of Radiographyen
dc.subjectChilden
dc.subjectArticleen
dc.subjectHumanen
dc.subjectAdulten
dc.subjectAgeden
dc.subjectControlled studyen
dc.subjectMajor clinical studyen
dc.subjectComputer assisted tomographyen
dc.subjectPriority journalen
dc.subjectAdolescenten
dc.subjectAge distributionen
dc.subjectPreschool childen
dc.subjectArtifacten
dc.subjectBrain tomographyen
dc.subjectContrast mediumen
dc.subjectImage processingen
dc.subjectImage reconstructionen
dc.subjectMotion artifactsen
dc.subjectSchool childen
dc.subjectSegmental reconstructionen
dc.subjectStreak artifactsen
dc.titleArtifacts in spiral CT protocols: The importance of the spatial reconstructionen
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1016/j.ejradi.2009.09.004
dc.description.volume1
dc.description.issue2
dc.description.startingpage73
dc.description.endingpage79
dc.author.facultyΙατρική Σχολή / Medical School
dc.author.departmentΙατρική Σχολή / Medical School
dc.type.uhtypeArticleen
dc.contributor.orcidWozniak, Greta [0000-0002-8939-0927]
dc.gnosis.orcid0000-0002-8939-0927


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record