dc.contributor.author | Kuzniz, T. | en |
dc.contributor.author | Halot, D. | en |
dc.contributor.author | Mignani, A. G. | en |
dc.contributor.author | Ciaccheri, L. | en |
dc.contributor.author | Kalli, Kyriacos | en |
dc.contributor.author | Tur, M. | en |
dc.contributor.author | Othonos, Andreas S. | en |
dc.contributor.author | Christofides, Constantinos | en |
dc.contributor.author | Jackson, D. A. | en |
dc.creator | Kuzniz, T. | en |
dc.creator | Halot, D. | en |
dc.creator | Mignani, A. G. | en |
dc.creator | Ciaccheri, L. | en |
dc.creator | Kalli, Kyriacos | en |
dc.creator | Tur, M. | en |
dc.creator | Othonos, Andreas S. | en |
dc.creator | Christofides, Constantinos | en |
dc.creator | Jackson, D. A. | en |
dc.date.accessioned | 2019-12-02T15:31:39Z | |
dc.date.available | 2019-12-02T15:31:39Z | |
dc.date.issued | 2007 | |
dc.identifier.issn | 0925-4005 | |
dc.identifier.uri | http://gnosis.library.ucy.ac.cy/handle/7/58811 | |
dc.description.abstract | The concentration of several pollutants, usually present in industrial waste waters, is predicted by the neural network data processing of absorption and fluorescence measurements in the visible spectral range. Proper network training provides quantitative analysis of many pollutants with sub-ppm resolution. Compact optical fibre instrumentation for absorption spectroscopy and an innovative flowcell for fluorescence measurements enable cost-effective, in situ, nonstop monitoring of waste waters. (c) 2006 Elsevier B.V. All rights reserved. | en |
dc.source | Sensors and Actuators B-Chemical | en |
dc.subject | water | en |
dc.subject | absorption spectroscopy | en |
dc.subject | fluorescence spectroscopy | en |
dc.subject | sensor | en |
dc.subject | fibre optics | en |
dc.subject | neural network analysis | en |
dc.subject | pollutants | en |
dc.title | Instrumentation for the monitoring of toxic pollutants in water resources by means of neural network analysis of absorption and fluorescence spectra | en |
dc.type | info:eu-repo/semantics/article | |
dc.identifier.doi | 10.1016/j.snb.2006.09.012 | |
dc.description.volume | 121 | |
dc.description.issue | 1 | |
dc.description.startingpage | 231 | |
dc.description.endingpage | 237 | |
dc.author.faculty | Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences | |
dc.author.department | Τμήμα Φυσικής / Department of Physics | |
dc.type.uhtype | Article | en |
dc.description.notes | <p>PT: J | en |
dc.description.notes | TC: 18 | en |
dc.description.notes | J9: SENSOR ACTUAT B-CHEM</p> | en |
dc.source.abbreviation | Sens.Actuator B-Chem. | en |
dc.contributor.orcid | Othonos, Andreas S. [0000-0003-0016-9116] | |
dc.contributor.orcid | Kalli, Kyriacos [0000-0003-4541-092X] | |
dc.contributor.orcid | Christofides, Constantinos [0000-0002-4020-4660] | |
dc.gnosis.orcid | 0000-0003-0016-9116 | |
dc.gnosis.orcid | 0000-0003-4541-092X | |
dc.gnosis.orcid | 0000-0002-4020-4660 | |