Show simple item record

dc.contributor.authorKyritsi, Eirinien
dc.contributor.authorMichael, Aimiliosen
dc.creatorKyritsi, Eirinien
dc.creatorMichael, Aimiliosen
dc.date.accessioned2021-01-22T09:26:41Z
dc.date.available2021-01-22T09:26:41Z
dc.date.issued2020
dc.identifier.issn0360-1323
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/61917
dc.description.abstractThe paper presents the key findings of a quantitative field research examining the impact of natural ventilation on the passive cooling of an office unit, in the Mediterranean region. The relevant unit was an open-plan office unit of a typical, medium-weight office building, in the urban centre of Nicosia—the capital of Cyprus—which is located in the Eastern Mediterranean Sea. During the fieldwork, air and globe temperature as well as air velocity—in both the indoor and the outdoor environment of the unit—were in-situ measured to evaluate the impact of different ventilation strategies on passive cooling, during the summer season. The first phase of the research aimed to assess the effectiveness of three ventilation strategies: daytime, night-time, and full-day ventilation. The outcomes confirmed that night ventilation is the most effective strategy in terms of passive cooling. The second, phase of the study was an in-depth examination of night-time ventilation using four different window and/or door opening patterns, i.e., two patterns of single-sided ventilation and two patterns of cross-ventilation. To complete the fieldwork, a third, and final, phase of the research examined the impact of the airflow on the thermal comfort zone in the case study building. By using quantitative indicators of thermal performance, including the Cooling Degree-Hours (CDH), the research showed that night-time cross-ventilation window patterns, as well as elevated airflow, drastically improved the indoor thermal conditions.en
dc.language.isoenen
dc.sourceBuilding and Environmenten
dc.source.urihttp://www.sciencedirect.com/science/article/pii/S0360132319305943
dc.titleAn assessment of the impact of natural ventilation strategies and window opening patterns in office buildings in the mediterranean basinen
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1016/j.buildenv.2019.106384
dc.description.volume175
dc.author.facultyΠολυτεχνική Σχολή / Faculty of Engineering
dc.author.departmentΤμήμα Αρχιτεκτονικής / Department of Architecture
dc.type.uhtypeArticleen
dc.source.abbreviationBuilding and Environmenten
dc.contributor.orcidMichael, Aimilios [0000-0001-8604-1054]
dc.gnosis.orcid0000-0001-8604-1054


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record