dc.description.abstractThrough the application of flexible Time-of-Use (ToU) tariffs, demand side management (DSM) can be facilitated in order to alleviate grid congestion problems and potential network reinforcement. In this work, a novel approach to derive ToU tariffs for residential prosumers is described and the potential impact is verified in a pilot network within the distribution grid of Cyprus comprised of three hundred prosumers. This pilot network acts as a test-bed for defining the baseline scenario and subsequently verifying the developed ToU tariffs. The ToU block periods were determined by combining statistical analysis and a hybrid optimization function that utilizes annealing driven pattern search algorithms. The ToU rates were calculated by exploiting an optimization function that maintained a neutral electricity bill in the case where the load profile remained unchanged. The impact of the derived ToU tariffs was first analysed through a sensitivity analysis performed on the seasonal load profiles of the participants. The obtained sensitivity analysis results showed that for the summer and winter season, the maximum Load Factor (LF) was 42.83% and 33.33% respectively and occurred when load was shifted mainly to the off-peak period. Finally, with the ToU tariffs applied to the pilot network of prosumers, the effectiveness and potential response of the prosumers to the imposed tariffs, was verified. The results indicated that the LF was increased while the percentage of total consumption measured during peak hours was reduced by 3.19%, 1.03% and 1.40% for the summer, middle and winter season respectively. This led to the conclusion that the derived ToU tariffs are effective in persuading the prosumers to change their energy behaviour.en
dc.language.isoenen
dc.sourceEnergyen
dc.source.urihttp://www.sciencedirect.com/science/article/pii/S0360544217317735
dc.titleDevelopment of a novel time-of-use tariff algorithm for residential prosumer price-based demand side managementen
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1016/j.energy.2017.10.068
dc.description.volume142
dc.description.startingpage633
dc.description.endingpage646
dc.author.facultyΠολυτεχνική Σχολή / Faculty of Engineering
dc.author.departmentΤμήμα Ηλεκτρολόγων Μηχανικών και Μηχανικών Υπολογιστών / Department of Electrical and Computer Engineering
dc.type.uhtypeArticleen
dc.source.abbreviationEnergyen
dc.contributor.orcidGeorghiou, George E. [0000-0002-5872-5851]
dc.contributor.orcidVenizelou, Venizelos [0000-0001-9545-0212]
dc.contributor.orcidMakrides, George [0000-0002-0327-0386]
dc.gnosis.orcid0000-0002-5872-5851
dc.gnosis.orcid0000-0001-9545-0212
dc.gnosis.orcid0000-0002-0327-0386


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record