Show simple item record

dc.contributor.authorIngenhoven, Philipen
dc.contributor.authorBelluardo, Giorgioen
dc.contributor.authorMakrides, Georgeen
dc.contributor.authorGeorghiou, George E.en
dc.contributor.authorRodden, Paulen
dc.contributor.authorFrearson, Lyndonen
dc.contributor.authorHerteleer, Berten
dc.contributor.authorBertani, Darioen
dc.contributor.authorMoser, Daviden
dc.creatorIngenhoven, Philipen
dc.creatorBelluardo, Giorgioen
dc.creatorMakrides, Georgeen
dc.creatorGeorghiou, George E.en
dc.creatorRodden, Paulen
dc.creatorFrearson, Lyndonen
dc.creatorHerteleer, Berten
dc.creatorBertani, Darioen
dc.creatorMoser, Daviden
dc.date.accessioned2021-01-26T09:45:32Z
dc.date.available2021-01-26T09:45:32Z
dc.date.issued2019
dc.identifier.issn2156-3403
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/63270
dc.description.abstractIn this paper, the annual performance loss rates (PLRs) of five different grid-connected photovoltaic (PV) technologies based on outdoor field measurements were computed. The data used were collected in five different geographical locations covering five climatic zones. The PLR values were determined as absolute and relative measures for all sites and module types using seasonal time series decomposition using local regression. The results are very consistent and show a clustering of the PLR for each technology, provided some explainable outliers are removed. This allows the conclusion that in presence of properly sized and quality-driven systems, the influence of different climates on the degradation of PV modules is not very strong. In the first approximation, individual degradations rate values computed in a single climatic zone can be seen as representative for the technology in general. The reason for this is that for defects there is an associated activation energy, which has not been reached yet in the systems analyzed in this study.en
dc.sourceIEEE Journal of Photovoltaicsen
dc.titleAnalysis of Photovoltaic Performance Loss Rates of Six Module Types in Five Geographical Locationsen
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1109/JPHOTOV.2019.2913342
dc.description.volume9
dc.description.issue4
dc.description.startingpage1091
dc.description.endingpage1096
dc.author.facultyΠολυτεχνική Σχολή / Faculty of Engineering
dc.author.departmentΤμήμα Ηλεκτρολόγων Μηχανικών και Μηχανικών Υπολογιστών / Department of Electrical and Computer Engineering
dc.type.uhtypeArticleen
dc.contributor.orcidGeorghiou, George E. [0000-0002-5872-5851]
dc.contributor.orcidMakrides, George [0000-0002-0327-0386]
dc.gnosis.orcid0000-0002-5872-5851
dc.gnosis.orcid0000-0002-0327-0386


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record