Show simple item record

dc.contributor.authorShachar-Berman, Lihien
dc.contributor.authorOstrovski, Yanen
dc.contributor.authorKoshiyama, Kenichiroen
dc.contributor.authorWada, Shigeoen
dc.contributor.authorKassinos, Stavros C.en
dc.contributor.authorSznitman, Josuéen
dc.creatorShachar-Berman, Lihien
dc.creatorOstrovski, Yanen
dc.creatorKoshiyama, Kenichiroen
dc.creatorWada, Shigeoen
dc.creatorKassinos, Stavros C.en
dc.creatorSznitman, Josuéen
dc.date.accessioned2021-01-27T10:17:27Z
dc.date.available2021-01-27T10:17:27Z
dc.date.issued2019
dc.identifier.issn0928-0987
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/63687
dc.description.abstractNon-spherical particles, and fibers in particular, are potentially attractive airborne carriers for pulmonary drug delivery. Not only do they exhibit a high surface-to-volume ratio relative to spherical aerosols, but their aerodynamic properties also enable them to reach deep into the lungs. Until present, however, our understanding of the deposition characteristics of inhaled aerosols in the distal acinar lung regions has been mostly limited to spheres. To shed light on the fate of elongated aerosols in the pulmonary depths, we explore through in silico numerical simulations the deposition and dispersion characteristics of ellipsoid-shaped fibers in a physiologically-realistic acinar geometry under oscillatory breathing flow conditions mimicking various inhalation maneuvers. The transient translation and rotational movement of micron-sized elongated particles under drag, lift, and gravitational forces are simulated as a function of size (dp) and aspect ratio (AR). Our findings underscore how acinar deposition characteristics are intimately linked to the geometrical combination of dp and AR under oscillatory flow conditions. Surprisingly, the elongation of the traditionally recommended size range of spherical particles (i.e., 2–3 μm) for acinar deposition may lead to a decrease in deposition efficiency and dispersion. Instead, our findings advocate how elongating particles (i.e., high AR) in the larger size range of 4–6 μm might be leveraged for improved targeted deposition to the acinar regions. Together, these results point to new windows of opportunities in selecting the shape and size of micron-sized fibers for targeted pulmonary deposition. Such in silico efforts represent an essential stepping stone in further exploring aerosol drug carrier designs for inhalation therapy to the deep lungs.en
dc.language.isoenen
dc.sourceEuropean Journal of Pharmaceutical Sciencesen
dc.source.urihttp://www.sciencedirect.com/science/article/pii/S0928098719302660
dc.titleTargeting inhaled fibers to the pulmonary acinus: Opportunities for augmented delivery from in silico simulationsen
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1016/j.ejps.2019.105003
dc.description.volume137
dc.author.facultyΠολυτεχνική Σχολή / Faculty of Engineering
dc.author.departmentΤμήμα Μηχανικών Μηχανολογίας και Κατασκευαστικής / Department of Mechanical and Manufacturing Engineering
dc.type.uhtypeArticleen
dc.source.abbreviationEuropean Journal of Pharmaceutical Sciencesen
dc.contributor.orcidKassinos, Stavros C. [0000-0002-3501-3851]
dc.gnosis.orcid0000-0002-3501-3851


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record