Show simple item record

dc.contributor.authorSokou, R.en
dc.contributor.authorFoudoulaki-Paparizos, Leontinien
dc.contributor.authorLytras, Theodorosen
dc.contributor.authorKonstantinidi, Aikaterinien
dc.contributor.authorTheodoraki, M.en
dc.contributor.authorLambadaridis, Ioannisen
dc.contributor.authorGounaris, Antonisen
dc.contributor.authorValsami, S.en
dc.contributor.authorPolitou, M.en
dc.contributor.authorGialeraki, Argirien
dc.contributor.authorNikolopoulos, Georgios K.en
dc.contributor.authorIacovidou, Nicolettaen
dc.contributor.authorBonovas, Stefanosen
dc.contributor.authorTsantes, Argirio E.en
dc.creatorSokou, R.en
dc.creatorFoudoulaki-Paparizos, Leontinien
dc.creatorLytras, Theodorosen
dc.creatorKonstantinidi, Aikaterinien
dc.creatorTheodoraki, M.en
dc.creatorLambadaridis, Ioannisen
dc.creatorGounaris, Antonisen
dc.creatorValsami, S.en
dc.creatorPolitou, M.en
dc.creatorGialeraki, Argirien
dc.creatorNikolopoulos, Georgios K.en
dc.creatorIacovidou, Nicolettaen
dc.creatorBonovas, Stefanosen
dc.creatorTsantes, Argirio E.en
dc.date.accessioned2018-06-22T09:53:14Z
dc.date.available2018-06-22T09:53:14Z
dc.date.issued2017
dc.identifier.urihttps://gnosis.library.ucy.ac.cy/handle/7/41732
dc.description.abstractRotational thromboelastometry (ROTEM) is an attractive method for rapid evaluation of hemostasis in neonates. Currently, no reference values exist for ROTEM assays in full-term and pre-term neonates. Our aim was to establish reference ranges for standard extrinsically activated ROTEM assay (EXTEM) in arterial blood samples of healthy full-term and pre-term neonates. In the present study, EXTEM assay was performed in 198 full-term (≥37 weeks' gestation) and 84 pre-term infants (<37 weeks' gestation) using peripheral arterial whole blood samples. Median values and reference ranges (2.5th and 97.5th percentiles) for the following main parameters of EXTEM assay were determined in full-term infants: Clotting time (seconds), 41 (range, 25.9-78); clot formation time (seconds), 70 (range, 40-165.2); maximum clot firmness (mm), 66 (range, 41-84.1); lysis index at 60 min (LI60, %), 97 (range, 85-100). The only parameter with a statistically significant difference between full-term and pre-term neonates was LI60 (p=0.006). Furthermore, it was inversely correlated with gestational age (p=0.002) and birth weight (p=0.016) in pre-term neonates. In conclusion, an enhanced fibrinolytic activity in pre-term neonates was noted. For most EXTEM assay parameters, reference ranges obtained from arterial newborn blood samples were comparable with the respective values from studies using cord blood. Modified reagents, small size samples, timing of sampling, and different kind of samples might account for any discrepancies among similar studies. Reference values hereby provided can be used in future studies. © 2017 2017 Walter de Gruyter GmbH, Berlin/Boston.en
dc.language.isoengen
dc.sourceClinical Chemistry and Laboratory Medicineen
dc.subjectNeonatesen
dc.subjectReference rangesen
dc.subjectThromboelastometryen
dc.titleReference ranges of thromboelastometry in healthy full-term and pre-term neonatesen
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1515/cclm-2016-0931
dc.description.volume55
dc.description.issue10
dc.description.startingpage1592
dc.description.endingpage1597
dc.author.facultyΙατρική Σχολή / Medical School
dc.author.departmentΙατρική Σχολή / Medical School
dc.type.uhtypeArticleen
dc.contributor.orcidNikolopoulos, Georgios K.[0000-0002-3307-0246]
dc.contributor.orcidBonovas, Stefanos [0000-0001-6102-6579]
dc.contributor.orcidIacovidou, Nicoletta [0000-0001-8021-6191]
dc.contributor.orcidTsantes, Argirio E. [0000-0001-8161-6672]
dc.gnosis.orcid0000-0002-3307-0246
dc.gnosis.orcid0000-0001-6102-6579
dc.gnosis.orcid0000-0001-8021-6191
dc.gnosis.orcid0000-0001-8161-6672


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record