Show simple item record

dc.contributor.authorXydas, E. G.en
dc.contributor.authorLouca, Loucas S.en
dc.creatorXydas, E. G.en
dc.creatorLouca, Loucas S.en
dc.date.accessioned2019-05-06T12:24:51Z
dc.date.available2019-05-06T12:24:51Z
dc.date.issued2008
dc.identifier.isbn0-7918-4303-3
dc.identifier.isbn978-0-7918-4303-1
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/48948
dc.description.abstractIn the area of rehabilitation robotics, many researchers have investigated the therapeutic effects of forces that are proportional to the difference of the user's hand trajectory with an optimum trajectory that is usually based on the Minimum Jerk Model (MJM). Forces applied in different studies were based on MJM trajectory variables, e.g., velocity, acceleration, position, etc. Consequently, MJM is a key component for upper limb robotic rehabilitation. However, it is critical to establish the validity of this model in the working environment prior of employing it as a reference control function. This work investigates the validity of the MJM under a haptic-virtual environment. The original 'real' tests (with no obstacles) that were employed for validating the MJM in planar motion are duplicated in a virtual environment. Haptic feedback is achieved with the use of a Phantom 1.5 High Force haptic interface. Experiments with healthy users are performed to investigate the validity of the MJM in virtual reality conditions. The experiments demonstrated that the MJM is also valid in virtual environments. Nevertheless it was found that in the virtual world, higher time durations are required for completing the tasks than in the real world. The results of this work will be used in the design of haptic-virtual environments for the rehabilitation of upper limbs of people with neuro-disabilities. Therapeutic forces based on the MJM can be applied given that the Minimum Jerk Model is valid in virtual environments. Copyright © 2007 by ASME.en
dc.language.isoengen
dc.publisherAffiliation: University of Cyprus, Department of Mechanical and Manufacturing Engineering, 75 Kallipoleos Street, Nicosia 1678, Cyprusen
dc.publisherCorrespondence Address: Xydas, E. G.en
dc.publisherUniversity of Cyprus, Department of Mechanical and Manufacturing Engineering, 75 Kallipoleos Street, Nicosia 1678, Cyprusen
dc.publisheremail: mep4ex1@ucy.ac.cyen
dc.sourceASME International Mechanical Engineering Congress and Exposition, Proceedingsen
dc.subjectRoboticsen
dc.subjectTrajectoriesen
dc.subjectBiomechanicsen
dc.subjectHaptic interfacesen
dc.subjectVirtual realityen
dc.subjectBiological organsen
dc.subjectPatient rehabilitationen
dc.subjectRobotic rehabilitationen
dc.subjectMinimum jerk modelen
dc.subjectHaptic feedbacken
dc.subjectHaptic virtual environmentsen
dc.subjectMinimum Jerk Model (MJM)en
dc.subjectReference controlen
dc.subjectRehabilitation roboticsen
dc.subjectTherapeutic effectsen
dc.subjectUpper limb motionen
dc.subjectUpper limb motion profileen
dc.subjectWorking environmenten
dc.titleUpper limb motion profile during small to medium time-limited reaching tasks in A VR based robotic training environmenten
dc.typeinfo:eu-repo/semantics/conferenceObject
dc.identifier.doi10.1115/IMECE2007-42220
dc.description.volume9 PART Ben
dc.description.startingpage1351
dc.description.endingpage1359
dc.author.facultyΠολυτεχνική Σχολή / Faculty of Engineering
dc.author.departmentΤμήμα Μηχανικών Μηχανολογίας και Κατασκευαστικής / Department of Mechanical and Manufacturing Engineering
dc.type.uhtypeConference Objecten
dc.contributor.orcidLouca, Loucas S. [0000-0002-0850-2369]
dc.description.totalnumpages1351-1359
dc.gnosis.orcid0000-0002-0850-2369


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record