Show simple item record

dc.contributor.authorJeromin, O. M.en
dc.contributor.authorPattichis, Marios S.en
dc.contributor.authorPattichis, Constantinos S.en
dc.contributor.authorKyriacou, Efthyvoulos C.en
dc.contributor.authorNicolaïdes, Andrew N.en
dc.creatorJeromin, O. M.en
dc.creatorPattichis, Marios S.en
dc.creatorPattichis, Constantinos S.en
dc.creatorKyriacou, Efthyvoulos C.en
dc.creatorNicolaïdes, Andrew N.en
dc.date.accessioned2019-11-13T10:40:25Z
dc.date.available2019-11-13T10:40:25Z
dc.date.issued2006
dc.identifier.isbn0-8194-6423-6
dc.identifier.isbn978-0-8194-6423-1
dc.identifier.isbn0-8194-6423-6
dc.identifier.isbn978-0-8194-6423-1
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/54113
dc.description.abstractStroke is the third leading cause of death in the western world and the major cause of disability in adults. The type and stenosis of extracranial carotid artery disease is often responsible for ischemic strokes, transient ischemic attacks (TIAs) or amaurosis fugax (AF). The identification and grading of stenosis can be done using gray scale ultrasound scans. The appearance of B-scan pictures containing various granular structures makes the use of texture analysis techniques suitable for computer assisted tissue characterization purposes. The objective of this study is to investigate the usefulness of variogram analysis in the assessment of ultrasound plague morphology. The variogram estimates the variance of random fields, from arbitrary samples in space. We explore stationary random field models based on the variogram, which can be applied in ultrasound plaque imaging leading to a Computer Aided Diagnosis (CAD) system for the early detection of symptomatic atherosclerotic plaques. Non-parametric tests on the variogram coefficients show that the coefficients coming from symptomatic versus asymptomatic plaques come from distinct distributions. Furthermore, we show significant improvement in class separation, when a log point-transformation is applied to the images, prior to variogram estimation. Model fitting using least squares is explored for anisotropic variograms along specific directions. Comparative classification results, show that variogram coefficients can be used for the early detection of symptomatic cases, and also exhibit the largest class distances between symptomatic and asymptomatic plaque images, as compared to over 60 other texture features, used in the literature.en
dc.sourceProgress in Biomedical Optics and Imaging - Proceedings of SPIEen
dc.sourceMedical Imaging 2006: Image Processingen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-33745119066&doi=10.1117%2f12.652355&partnerID=40&md5=e207c4293fc1ef9c91d832b5f8191773
dc.subjectMathematical modelsen
dc.subjectUltrasounden
dc.subjectUltrasonic imagingen
dc.subjectImage analysisen
dc.subjectMedical imagingen
dc.subjectCardiologyen
dc.subjectTexturesen
dc.subjectVariogramen
dc.subjectComputer aided diagnosisen
dc.subjectAtherosclerotic Plaque Classificationen
dc.subjectGranular structuresen
dc.subjectTexture Classificationen
dc.titleVariogram methods for texture classification of atherosclerotic plaque ultrasound imagesen
dc.typeinfo:eu-repo/semantics/conferenceObject
dc.identifier.doi10.1117/12.652355
dc.description.volume6144 Ien
dc.author.faculty002 Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences
dc.author.departmentΤμήμα Πληροφορικής / Department of Computer Science
dc.type.uhtypeConference Objecten
dc.description.notes<p>Conference code: 67519</p>en
dc.contributor.orcidPattichis, Constantinos S. [0000-0003-1271-8151]
dc.contributor.orcidPattichis, Marios S. [0000-0002-1574-1827]
dc.contributor.orcidKyriacou, Efthyvoulos C. [0000-0002-4589-519X]
dc.gnosis.orcid0000-0003-1271-8151
dc.gnosis.orcid0000-0002-1574-1827
dc.gnosis.orcid0000-0002-4589-519X


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record