dc.contributor.author | Kyriacou, Efthyvoulos C. | en |
dc.contributor.author | Pavlopoulos, Sotirios A. | en |
dc.contributor.author | Berler, A. | en |
dc.contributor.author | Neophytou, Marios | en |
dc.contributor.author | Bourka, A. | en |
dc.contributor.author | Georgoulas, Aggelos | en |
dc.contributor.author | Anagnostaki, Anthoula P. | en |
dc.contributor.author | Karayiannis, D. | en |
dc.contributor.author | Schizas, Christos N. | en |
dc.contributor.author | Pattichis, Constantinos S. | en |
dc.contributor.author | Andreou, Andreas S. | en |
dc.contributor.author | Koutsouris, Demetrios Dionysios | en |
dc.creator | Kyriacou, Efthyvoulos C. | en |
dc.creator | Pavlopoulos, Sotirios A. | en |
dc.creator | Berler, A. | en |
dc.creator | Neophytou, Marios | en |
dc.creator | Bourka, A. | en |
dc.creator | Georgoulas, Aggelos | en |
dc.creator | Anagnostaki, Anthoula P. | en |
dc.creator | Karayiannis, D. | en |
dc.creator | Schizas, Christos N. | en |
dc.creator | Pattichis, Constantinos S. | en |
dc.creator | Andreou, Andreas S. | en |
dc.creator | Koutsouris, Demetrios Dionysios | en |
dc.date.accessioned | 2019-11-13T10:40:53Z | |
dc.date.available | 2019-11-13T10:40:53Z | |
dc.date.issued | 2003 | |
dc.identifier.issn | 1475-925X | |
dc.identifier.uri | http://gnosis.library.ucy.ac.cy/handle/7/54341 | |
dc.description.abstract | The provision of effective emergency telemedicine and home monitoring solutions are the major fields of interest discussed in this study. Ambulances, Rural Health Centers (RHC) or other remote health location such as Ships navigating in wide seas are common examples of possible emergency sites, while critical care telemetry and telemedicine home follow-ups are important issues of telemonitoring. In order to support the above different growing application fields we created a combined real-time and store and forward facility that consists of a base unit and a telemedicine (mobile) unit. This integrated system: can be used when handling emergency cases in ambulances, RHC or ships by using a mobile telemedicine unit at the emergency site and a base unit at the hospital-expert's site, enhances intensive health care provision by giving a mobile base unit to the ICU doctor while the telemedicine unit remains at the ICU patient site and enables home telemonitoring, by installing the telemedicine unit at the patient's home while the base unit remains at the physician's office or hospital. The system allows the transmission of vital biosignals (3-12 lead ECG, SPO2, NIBP, IBP, Temp) and still images of the patient. The transmission is performed through GSM mobile telecommunication network, through satellite links (where GSM is not available) or through Plain Old Telephony Systems (POTS) where available. Using this device a specialist doctor can telematically "move" to the patient's site and instruct unspecialized personnel when handling an emergency or telemonitoring case. Due to the need of storing and archiving of all data interchanged during the telemedicine sessions, we have equipped the consultation site with a multimedia database able to store and manage the data collected by the system. The performance of the system has been technically tested over several telecommunication means | en |
dc.description.abstract | in addition the system has been clinically validated in three different countries using a standardized medical protocol. © 2003 Kyriacou et al | en |
dc.description.abstract | licensee BioMed Central Ltd. | en |
dc.source | BioMedical Engineering Online | en |
dc.source.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-1942520082&doi=10.1186%2f1475-925X-2-7&partnerID=40&md5=2ad63fa6a8f44160e5d3fb710d08b81e | |
dc.subject | article | en |
dc.subject | standardization | en |
dc.subject | feasibility study | en |
dc.subject | procedures | en |
dc.subject | patient monitoring | en |
dc.subject | Feasibility Studies | en |
dc.subject | validation process | en |
dc.subject | clinical protocol | en |
dc.subject | data base | en |
dc.subject | organization and management | en |
dc.subject | intensive care unit | en |
dc.subject | health care system | en |
dc.subject | medical specialist | en |
dc.subject | classification | en |
dc.subject | health center | en |
dc.subject | information processing | en |
dc.subject | devices | en |
dc.subject | image processing | en |
dc.subject | physician | en |
dc.subject | consultation | en |
dc.subject | evaluation study | en |
dc.subject | emergency health service | en |
dc.subject | medical expert | en |
dc.subject | medical information system | en |
dc.subject | health care delivery | en |
dc.subject | telecommunication | en |
dc.subject | Telecommunications | en |
dc.subject | oxygen | en |
dc.subject | temperature measurement | en |
dc.subject | Monitoring, Physiologic | en |
dc.subject | non invasive measurement | en |
dc.subject | Telemedicine | en |
dc.subject | home care | en |
dc.subject | physiologic monitoring | en |
dc.subject | mobile phone | en |
dc.subject | ambulance | en |
dc.subject | blood pressure monitoring | en |
dc.subject | Data Compression | en |
dc.subject | electrocardiography | en |
dc.subject | Emergency health care | en |
dc.subject | GSM | en |
dc.subject | health care facility | en |
dc.subject | hospital service | en |
dc.subject | medical instrumentation | en |
dc.subject | medical personnel | en |
dc.subject | multimedia | en |
dc.subject | oxygen saturation | en |
dc.subject | rural health care | en |
dc.subject | Satellite | en |
dc.subject | ship | en |
dc.subject | telephone | en |
dc.title | Multi-purpose healthcare telemedicine systems with mobile communication link support | en |
dc.type | info:eu-repo/semantics/article | |
dc.identifier.doi | 10.1186/1475-925X-2-7 | |
dc.description.volume | 2 | |
dc.author.faculty | 002 Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences | |
dc.author.department | Τμήμα Πληροφορικής / Department of Computer Science | |
dc.type.uhtype | Article | en |
dc.description.notes | <p>Tradenames: Borland Delphi 5 | en |
dc.description.notes | Connectix | en |
dc.description.notes | CRITIKON DINAMAP PLUS Monitor Model 8200, Critikon | en |
dc.description.notes | CRITIKON DINAMAP PLUS Monitor Model 9700, Critikon | en |
dc.description.notes | Logitech | en |
dc.description.notes | Micronet | en |
dc.description.notes | Option FirstFone | en |
dc.description.notes | Pentium | en |
dc.description.notes | PROTOCOL-Welch Allyn Propaq 1xx Vital Signs Monitor, Welch Allyn | en |
dc.description.notes | PROTOCOL-Welch Allyn Propaq Encore 2xx Vital Signs Monitor, Welch Allyn | en |
dc.description.notes | Toshiba libretto 100 ct portable PC, Toshiba | en |
dc.description.notes | TT-3064A CAPSAT Inmarsat Maritime Phone, Thrane and Thrane | en |
dc.description.notes | US-Robotics | en |
dc.description.notes | Windows 2000, Microsoft | en |
dc.description.notes | Windows 95, Microsoft | en |
dc.description.notes | Windows 98, Microsoft | en |
dc.description.notes | Windows NT, Microsoft | en |
dc.description.notes | Windows, Microsoft | en |
dc.description.notes | Manufacturers: Critikon | en |
dc.description.notes | Microsoft | en |
dc.description.notes | Nokia | en |
dc.description.notes | Thrane and Thrane | en |
dc.description.notes | Toshiba | en |
dc.description.notes | Welch Allyn | en |
dc.description.notes | Cited By :104</p> | en |
dc.source.abbreviation | Biomedical Eng.Online | en |
dc.contributor.orcid | Schizas, Christos N. [0000-0001-6548-4980] | |
dc.contributor.orcid | Pattichis, Constantinos S. [0000-0003-1271-8151] | |
dc.contributor.orcid | Andreou, Andreas S. [0000-0001-7104-2097] | |
dc.contributor.orcid | Kyriacou, Efthyvoulos C. [0000-0002-4589-519X] | |
dc.gnosis.orcid | 0000-0001-6548-4980 | |
dc.gnosis.orcid | 0000-0003-1271-8151 | |
dc.gnosis.orcid | 0000-0001-7104-2097 | |
dc.gnosis.orcid | 0000-0002-4589-519X | |