dc.contributor.author | Loizou, Christos P. | en |
dc.contributor.author | Christodoulou, Chris C. | en |
dc.contributor.author | Pattichis, Constantinos S. | en |
dc.contributor.author | Istepanian, Robert Sh Habib | en |
dc.contributor.author | Pantzaris, Marios C. | en |
dc.contributor.author | Nicolaïdes, Andrew N. | en |
dc.contributor.editor | Skodras A.N. | en |
dc.contributor.editor | Constantinides, Anthony G. | en |
dc.creator | Loizou, Christos P. | en |
dc.creator | Christodoulou, Chris C. | en |
dc.creator | Pattichis, Constantinos S. | en |
dc.creator | Istepanian, Robert Sh Habib | en |
dc.creator | Pantzaris, Marios C. | en |
dc.creator | Nicolaïdes, Andrew N. | en |
dc.date.accessioned | 2019-11-13T10:41:01Z | |
dc.date.available | 2019-11-13T10:41:01Z | |
dc.date.issued | 2002 | |
dc.identifier.isbn | 0-7803-7503-3 | |
dc.identifier.uri | http://gnosis.library.ucy.ac.cy/handle/7/54412 | |
dc.description.abstract | The objective of this work was to develop six speckle reduction-filtering techniques and evaluate them together with texture analysis in the assessment of 240 ultrasound images of the carotid artery. The de- speckled filters are based on anisotropic diffusion, local statistics with higher moments, and geometric filtering. Results showed that some improvement in class separation (between symptomatic and asymptomatic plaques) of the images was evident after de-speckle filtering. © 2002 IEEE. | en |
dc.publisher | Institute of Electrical and Electronics Engineers Inc. | en |
dc.source | International Conference on Digital Signal Processing, DSP | en |
dc.source | 14th International Conference on Digital Signal Processing, DSP 2002 | en |
dc.source.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84948695004&doi=10.1109%2fICDSP.2002.1028143&partnerID=40&md5=abf4dcbf55f638d0a7db238f5167252c | |
dc.subject | Signal processing | en |
dc.subject | Digital signal processing | en |
dc.subject | Ultrasonics | en |
dc.subject | Filtering technique | en |
dc.subject | Speckle | en |
dc.subject | Texture analysis | en |
dc.subject | Ultrasound images | en |
dc.subject | Anisotropic Diffusion | en |
dc.subject | Geometric filtering | en |
dc.subject | Local statistics | en |
dc.subject | Speckle filtering | en |
dc.subject | Speckle reduction | en |
dc.title | Speckle reduction in ultrasound images of atherosclerotic carotid plaque | en |
dc.type | info:eu-repo/semantics/conferenceObject | |
dc.identifier.doi | 10.1109/ICDSP.2002.1028143 | |
dc.description.volume | 2 | |
dc.description.startingpage | 525 | |
dc.description.endingpage | 528 | |
dc.author.faculty | 002 Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences | |
dc.author.department | Τμήμα Πληροφορικής / Department of Computer Science | |
dc.type.uhtype | Conference Object | en |
dc.description.notes | <p>Sponsors: | en |
dc.description.notes | Conference code: 115913 | en |
dc.description.notes | Cited By :27</p> | en |
dc.contributor.orcid | Pattichis, Constantinos S. [0000-0003-1271-8151] | |
dc.contributor.orcid | Christodoulou, Chris C. [0000-0001-9398-5256] | |
dc.contributor.orcid | Loizou, Christos P. [0000-0003-1247-8573] | |
dc.contributor.orcid | Pantzaris, Marios C. [0000-0003-2937-384X] | |
dc.gnosis.orcid | 0000-0003-1271-8151 | |
dc.gnosis.orcid | 0000-0001-9398-5256 | |
dc.gnosis.orcid | 0000-0003-1247-8573 | |
dc.gnosis.orcid | 0000-0003-2937-384X | |