Show simple item record

dc.contributor.authorLoizou, Christos P.en
dc.contributor.authorLoizou, Christos P.en
dc.contributor.authorMatamis, D.en
dc.contributor.authorSoleimezi, E.en
dc.contributor.authorMinas, G.en
dc.contributor.authorPattichis, Constantinos S.en
dc.contributor.editorKyriacou, Efthyvoulos C.en
dc.contributor.editorChristofides, Steliosen
dc.contributor.editorPattichis, Constantinos S.en
dc.creatorLoizou, Christos P.en
dc.creatorLoizou, Christos P.en
dc.creatorMatamis, D.en
dc.creatorSoleimezi, E.en
dc.creatorMinas, G.en
dc.creatorPattichis, Constantinos S.en
dc.date.accessioned2019-11-13T10:41:02Z
dc.date.available2019-11-13T10:41:02Z
dc.date.issued2016
dc.identifier.isbn978-3-319-32701-3
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/54419
dc.description.abstractMeasurements of ultrasound diaphragmatic motion may provide important and essential information about diaphragmatic fatigue. In this work, we propose a semiautomated analysis system for measuring the diaphragmatic motion and estimation of the maximum relaxation rate (MRR) from ultrasound M-mode images of the diaphragmatic muscle. The proposed system was evaluated in three ultrasound images of the diaphragmatic muscle. The system is able to compute the diaphragmatic motion and extract quantitative parameters for systolic and diastolic times as well as the excursion, inspiration, cycle duration and the MRR. The proposed system was evaluated by a clinical expert. It is anticipated that it might be used in future in the clinical practice. Further validation and additional experimentation in a larger sample of images is required for further validating the system. © Springer International Publishing Switzerland 2016.en
dc.publisherSpringer Verlagen
dc.sourceIFMBE Proceedingsen
dc.source14th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2016en
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84968561636&doi=10.1007%2f978-3-319-32703-7_70&partnerID=40&md5=f66872ebbcc89442e28da2536397fa43
dc.subjectMuscleen
dc.subjectUltrasonic applicationsen
dc.subjectBiochemical engineeringen
dc.subjectMedical computingen
dc.subjectRelaxation ratesen
dc.subjectUltrasound imagesen
dc.subjectClinical practicesen
dc.subjectCycle durationen
dc.subjectDiaphragmatic motion analysisen
dc.subjectDiaphragmatic muscleen
dc.subjectDiaphragmatic ultrasounden
dc.subjectMaximum relaxation rate (MRR)en
dc.subjectMeasurements ofen
dc.subjectQuantitative parametersen
dc.subjectSemi-automated analysisen
dc.subjectSonographicen
dc.titleSuggesting a sonographic index to measure ultrasound diaphragmatic MRRen
dc.typeinfo:eu-repo/semantics/conferenceObject
dc.identifier.doi10.1007/978-3-319-32703-7_70
dc.description.volume57
dc.description.startingpage355
dc.description.endingpage360
dc.author.faculty002 Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences
dc.author.departmentΤμήμα Πληροφορικής / Department of Computer Science
dc.type.uhtypeConference Objecten
dc.description.notes<p>Sponsors:en
dc.description.notesConference code: 172989</p>en
dc.contributor.orcidPattichis, Constantinos S. [0000-0003-1271-8151]
dc.contributor.orcidKyriacou, Efthyvoulos C. [0000-0002-4589-519X]
dc.contributor.orcidLoizou, Christos P. [0000-0003-1247-8573]
dc.gnosis.orcid0000-0003-1271-8151
dc.gnosis.orcid0000-0002-4589-519X
dc.gnosis.orcid0000-0003-1247-8573


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record