Show simple item record

dc.contributor.authorLoizou, Christos P.en
dc.contributor.authorPantzaris, Marios C.en
dc.contributor.authorPattichis, Constantinos S.en
dc.contributor.authorKyriacou, Efthyvoulos C.en
dc.creatorLoizou, Christos P.en
dc.creatorPantzaris, Marios C.en
dc.creatorPattichis, Constantinos S.en
dc.creatorKyriacou, Efthyvoulos C.en
dc.date.accessioned2019-11-13T10:41:04Z
dc.date.available2019-11-13T10:41:04Z
dc.date.issued2010
dc.identifier.isbn978-1-4244-6285-8
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/54430
dc.description.abstractMonitoring the wall and plaque changes in the carotid artery (CA) can provide useful information for the assessment of the atherosclerotic disease. Using a motion mode (M-mode) image, detailed information may be obtained about wall and lumen dimensions, systolic and diastolic artery diameter and distension, wall and plaque motion and thickness, and also their corresponding states (timings). The wall thickness and the diameter of the CA change during the cardiac cycle are an indicator of regional contraction and therefore an indication of a disease. The objective of this work was to investigate how M-mode state based modeling of the CA can be derived from a B-mode ultrasound video. Briefly, 10 longitudinal CA ultrasound videos acquired from symptomatic subjects at risk of atherosclerosis were broken into frames and their M-mode images were generated. These were then despeckled and the atherosclerotic carotid plaque was segmented from each video, in order to extract the states of the video. By identifying the states of the CA, we can distinguish between normal and abnormal plaque motion. It was shown in this work, that M-mode state based modeling derived from B-mode videos can be used successfully to derive the carotid states and assess the corresponding wall changes. However, further work in a larger number of videos is needed for validating the proposed method and to differentiate between normal and abnormal state based plaque motion analysis. ©2010 IEEE.en
dc.sourceFinal Program and Abstract Book - 4th International Symposium on Communications, Control, and Signal Processing, ISCCSP 2010en
dc.source4th International Symposium on Communications, Control, and Signal Processing, ISCCSP-2010en
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-77953862025&doi=10.1109%2fISCCSP.2010.5463375&partnerID=40&md5=aab88191e33d9815794cf86dc80cd5e7
dc.subjectSignal processingen
dc.subjectState-baseden
dc.subjectMotion analysisen
dc.subjectUltrasonicsen
dc.subjectCarotid arteryen
dc.subjectCarotid plaquesen
dc.subjectCardiac cyclesen
dc.subjectCorresponding stateen
dc.subjectMode-stateen
dc.subjectMotion modesen
dc.subjectWall thicknessen
dc.titleM-mode state based identification in ultrasound videos of the atherosclerotic carotid plaqueen
dc.typeinfo:eu-repo/semantics/conferenceObject
dc.identifier.doi10.1109/ISCCSP.2010.5463375
dc.author.faculty002 Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences
dc.author.departmentΤμήμα Πληροφορικής / Department of Computer Science
dc.type.uhtypeConference Objecten
dc.description.notes<p>Sponsors: Cyprus University of Technologyen
dc.description.notesUniversity of Cyprusen
dc.description.notesConference code: 80672en
dc.description.notesCited By :8</p>en
dc.contributor.orcidPattichis, Constantinos S. [0000-0003-1271-8151]
dc.contributor.orcidKyriacou, Efthyvoulos C. [0000-0002-4589-519X]
dc.contributor.orcidLoizou, Christos P. [0000-0003-1247-8573]
dc.contributor.orcidPantzaris, Marios C. [0000-0003-2937-384X]
dc.gnosis.orcid0000-0003-1271-8151
dc.gnosis.orcid0000-0002-4589-519X
dc.gnosis.orcid0000-0003-1247-8573
dc.gnosis.orcid0000-0003-2937-384X


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record