Show simple item record

dc.contributor.authorLoizou, Christos P.en
dc.contributor.authorPetroudi, Stylianien
dc.contributor.authorPattichis, Constantinos S.en
dc.contributor.authorPantzaris, Marios C.en
dc.contributor.authorKasparis, Takisen
dc.contributor.authorNicolaïdes, Andrew N.en
dc.creatorLoizou, Christos P.en
dc.creatorPetroudi, Stylianien
dc.creatorPattichis, Constantinos S.en
dc.creatorPantzaris, Marios C.en
dc.creatorKasparis, Takisen
dc.creatorNicolaïdes, Andrew N.en
dc.date.accessioned2019-11-13T10:41:06Z
dc.date.available2019-11-13T10:41:06Z
dc.date.issued2012
dc.identifier.isbn978-1-4244-4119-8
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/54452
dc.description.abstractThe degree of stenosis of the common carotid artery (CCA) but also the characteristics of the arterial wall including plaque size, composition and elasticity represent important predictors used in the assessment of the risk for future cardiovascular events. This paper proposes and evaluates an integrated system for the segmentation of atherosclerotic carotid plaque in ultrasound video of the CCA based on normalization, speckle reduction filtering (with the hybrid median filter) and parametric active contours. The algorithm is initialized in the first video frame of the cardiac cycle with human assistance and the moving atherosclerotic plaque borders are tracked and segmented in the subsequent frames. The algorithm is evaluated on 10 real CCA digitized videos from B-mode longitudinal ultrasound segments and is compared with the manual segmentations of an expert, for every 20 frames in a time span of 3-5 seconds, covering in general 2 cardiac cycles. The segmentation results are very satisfactory with a true negative fraction (TNF) of 79.3%, a true-positive fraction (TPF) of 78.12%, a false-positive fraction (FPF) of 6.7% and a false-negative fraction (FNF) of 19.6% between the ground truth and the presented plaque segmentations, a Williams index (KI) of 80.3%, an overlap index of 71.5%, a specificity of 0.88±0.09, a precision of 0.86±0.10 and an effectiveness measure of 0.77±0.09. The results show that integrated system investigated in this study could be successfully used for the automated video segmentation of the carotid plaque. © 2012 IEEE.en
dc.sourceProceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBSen
dc.source34th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2012en
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84870840032&doi=10.1109%2fEMBC.2012.6345869&partnerID=40&md5=d01a66b9ab25c07d4a285f7a7a98285b
dc.subjectAlgorithmsen
dc.subjectIntegrated controlen
dc.subjectElasticityen
dc.subjectUltrasonicsen
dc.subjectPotassium iodideen
dc.subjectCommon carotid arteryen
dc.subjectImage segmentationen
dc.subjectCarotid plaquesen
dc.subjectIntegrated systemsen
dc.subjectAtherosclerotic plaqueen
dc.subjectArterial wallen
dc.subjectSpeckle reductionen
dc.subjectVideo frameen
dc.subjectCardiac cyclesen
dc.subjectCardiovascular eventen
dc.subjectTime spanen
dc.subjectManual segmentationen
dc.subjectParametric active contoursen
dc.subjectSegmentation resultsen
dc.subjectAutomated videoen
dc.subjectEffectiveness measureen
dc.subjectGround truthen
dc.subjectHuman assistanceen
dc.subjectTrue negativeen
dc.subjectWilliamsen
dc.titleSegmentation of atherosclerotic carotid plaque in ultrasound videoen
dc.typeinfo:eu-repo/semantics/conferenceObject
dc.identifier.doi10.1109/EMBC.2012.6345869
dc.description.startingpage53
dc.description.endingpage56
dc.author.faculty002 Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences
dc.author.departmentΤμήμα Πληροφορικής / Department of Computer Science
dc.type.uhtypeConference Objecten
dc.description.notes<p>Sponsors: IEEE EMBen
dc.description.notesIEEE CASen
dc.description.notesIEEE SMCen
dc.description.notesSONNETen
dc.description.notesConference code: 94236en
dc.description.notesCited By :3</p>en
dc.contributor.orcidPattichis, Constantinos S. [0000-0003-1271-8151]
dc.contributor.orcidLoizou, Christos P. [0000-0003-1247-8573]
dc.contributor.orcidPantzaris, Marios C. [0000-0003-2937-384X]
dc.gnosis.orcid0000-0003-1271-8151
dc.gnosis.orcid0000-0003-1247-8573
dc.gnosis.orcid0000-0003-2937-384X


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record