dc.description.abstractThe radioactivity concentration of 236Pu, 232U and 228Th in aqueous samples has been determined by means of alpha spectroscopy after chemical separation and pre-concentration of the radionuclides by cation exchange and liquid-liquid extraction using the Chelex-100 resin and 30% TBP/dodecan, respectively. Method calibration using a 236Pu standard solution containing the daughter radionuclides results in a detector efficiency of 18% and in a chemical recovery for cation-exchange which is (30 ± 7)%, (90 ± 5)% and (20 ± 5)% for plutonium, uranium and thorium, respectively. The chemical recovery for liquid-liquid extraction is found to be (60 ± 7)%, (50 ± 5)% and (70 ± 5)%, for plutonium, uranium and thorium, respectively. The differences in the efficiencies can be ascribed to the oxidation states, the different actinides present in solution. Taking into account that the electrodeposition of the radionuclides under study is quantitative, the total method efficiency is calculated to be (18 ± 15)%, (46 ± 7)% and (15 ± 5)%, for plutonium, uranium and thorium, respectively, at the mBq concentration range. The detection limit of the alpha spectrometric system has been found to be 0.2 mBq/L, suggesting that the method could be successfully applied for the radiometric analysis of the studied radionuclides and particularly uranium in aqueous samples. © 2010 Akadémiai Kiadó.en
dc.sourceJournal of Radioanalytical and Nuclear Chemistryen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-77953024696&doi=10.1007%2fs10967-010-0527-3&partnerID=40&md5=2a7237a282781ce4edcee58e1c4f98f2
dc.subjectarticleen
dc.subjectquantitative analysisen
dc.subjectunclassified drugen
dc.subjectradioisotopeen
dc.subjectcalibrationen
dc.subjectconcentration (parameters)en
dc.subjectaqueous solutionen
dc.subjectspectroscopyen
dc.subjectthoriumen
dc.subjecturaniumen
dc.subjectoxidationen
dc.subjectLiquid extractionen
dc.subjectActinidesen
dc.subjectliquid liquid extractionen
dc.subjectAlpha spectroscopyen
dc.subjectcation exchangeen
dc.subjectCation-exchangeen
dc.subjectactinideen
dc.subjectresinen
dc.subjectChemical recoveriesen
dc.subjectOxidation stateen
dc.subjectplutoniumen
dc.subjectplutonium 236en
dc.subjectthorium 228en
dc.subjecturanium 232en
dc.titleAlpha spectroscopic analysis of actinides (Th, U and Pu) after separation from aqueous solutions by cation-exchange and liquid extractionen
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1007/s10967-010-0527-3
dc.description.volume284
dc.description.issue3
dc.description.startingpage547
dc.description.endingpage551
dc.author.faculty002 Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences
dc.author.departmentΤμήμα Χημείας / Department of Chemistry
dc.type.uhtypeArticleen
dc.description.notes<p>Cited By :21</p>en
dc.source.abbreviationJ.Radioanal.Nucl.Chem.en
dc.contributor.orcidPashalidis, Ioannis [0000-0002-7587-6395]
dc.gnosis.orcid0000-0002-7587-6395


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record