dc.contributor.author | Mitrofan, Grigorina | en |
dc.contributor.author | Stefan-Van Staden, R. I. | en |
dc.contributor.author | Moldoveanu, I. | en |
dc.contributor.author | Kapnissi‐Christodoulou, Constantina P. | en |
dc.creator | Mitrofan, Grigorina | en |
dc.creator | Stefan-Van Staden, R. I. | en |
dc.creator | Moldoveanu, I. | en |
dc.creator | Kapnissi‐Christodoulou, Constantina P. | en |
dc.date.accessioned | 2019-11-21T06:21:31Z | |
dc.date.available | 2019-11-21T06:21:31Z | |
dc.date.issued | 2017 | |
dc.identifier.issn | 1454-2331 | |
dc.identifier.uri | http://gnosis.library.ucy.ac.cy/handle/7/55865 | |
dc.description.abstract | A new enantioselective, potentiometric microsensor based on ionic liquid L-Ala-C4-NO3-L-lac was designed and used for the assay of L-thyroxyne (L-T4) in its pharmaceutical formulations. The matrix used for the design of the microsensor was carbon nanopowder. The limit of detection obtained for L-T4 using this sensor was 5×10-7 mol/L, the linear concentration range was between 10-9 and 10-7 mol/L L-T4. The average recovery of L-T4 in pharmaceutical formulations was 96.15%. | en |
dc.source | UPB Scientific Bulletin, Series B: Chemistry and Materials Science | en |
dc.source.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85014740410&partnerID=40&md5=c735d15fe4b8f7cb0deb1d374bd28894 | |
dc.subject | Liquids | en |
dc.subject | Nanostructured materials | en |
dc.subject | Ionic liquids | en |
dc.subject | Potentiometers (electric measuring instruments) | en |
dc.subject | Average recovery | en |
dc.subject | Carbon nanopowder | en |
dc.subject | Carbon nanopowders | en |
dc.subject | Enantioselective | en |
dc.subject | L-Ala-C4-NO3-L-lac ionic liquid | en |
dc.subject | L-thyroxine | en |
dc.subject | Limit of detection | en |
dc.subject | Linear concentration | en |
dc.subject | Microsensors | en |
dc.subject | Pharmaceutical formulation | en |
dc.subject | Pharmaceutical formulations | en |
dc.subject | Potentiometric | en |
dc.subject | Potentiometric microsensors | en |
dc.title | Analysis of l-thyroxine from pharmaceutical formulations using a potentio metricmicrosensor based on ionic liquid | en |
dc.type | info:eu-repo/semantics/article | |
dc.description.volume | 79 | |
dc.description.issue | 1 | |
dc.description.startingpage | 111 | |
dc.description.endingpage | 118 | |
dc.author.faculty | 002 Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences | |
dc.author.department | Τμήμα Χημείας / Department of Chemistry | |
dc.type.uhtype | Article | en |
dc.source.abbreviation | UPB Sci Bull Ser B | en |
dc.contributor.orcid | Kapnissi‐Christodoulou, Constantina P. [0000-0003-3755-1052] | |
dc.gnosis.orcid | 0000-0003-3755-1052 | |