Show simple item record

dc.contributor.authorStefan-Van Staden, R. -Ien
dc.contributor.authorMoldoveanu, I.en
dc.contributor.authorSava, D. -Fen
dc.contributor.authorKapnissi‐Christodoulou, Constantina P.en
dc.contributor.authorVan Staden, J. F.en
dc.creatorStefan-Van Staden, R. -Ien
dc.creatorMoldoveanu, I.en
dc.creatorSava, D. -Fen
dc.creatorKapnissi‐Christodoulou, Constantina P.en
dc.creatorVan Staden, J. F.en
dc.date.accessioned2019-11-21T06:23:00Z
dc.date.available2019-11-21T06:23:00Z
dc.date.issued2013
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/56166
dc.description.abstractStochastic and potentiometric microsensors based on porphyrins and polymeric surfactants such as polysodium N-undecanoyl- l-leucylvanilate and polysodium N-undecanoyl- l-vanilate were developed for enantioselective assay of pipecolic acid. The matrices used for the design of the stochastic sensors were diamond paste and graphite paste, while the matrix used for the design of potentiometric sensors was carbon paste. The response characteristics of the microsensors were determined for the enantiomers of pipecolic acid. The response characteristics, selectivity, and enantioselectivity studies proved that the proposed microsensors can be used for clinical enantioanalysis of pipecolic acid in biological fluids, e.g., urine and whole blood. Copyright © 2012 Wiley Periodicals, Inc.en
dc.sourceChiralityen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84872831044&doi=10.1002%2fchir.22119&partnerID=40&md5=5ce8395de48d685d306a3f7cbe255cf6
dc.subjectarticleen
dc.subjectHumansen
dc.subjectpriority journalen
dc.subjectsurfactanten
dc.subjectbody fluiden
dc.subjectpolymeren
dc.subjectcarbonen
dc.subjectgraphiteen
dc.subjectStereoisomerismen
dc.subjectpotentiometryen
dc.subjectenantioselectivityen
dc.subjectpipecolic aciden
dc.subjectPipecolic Acidsen
dc.subjectsensoren
dc.subjectChemistry Techniques, Analyticalen
dc.subjectclinical enantioanalysisen
dc.subjectdiamonden
dc.subjectmicroelectrodeen
dc.subjectmicrosensoren
dc.subjectporphyrin derivativeen
dc.subjectpotentiometric sensorsen
dc.subjectStochastic Processesen
dc.subjectstochastic sensorsen
dc.titleEnantioanalysis of pipecolic acid with stochastic and potentiometric microsensorsen
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1002/chir.22119
dc.description.volume25
dc.description.issue2
dc.description.startingpage114
dc.description.endingpage118
dc.author.faculty002 Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences
dc.author.departmentΤμήμα Χημείας / Department of Chemistry
dc.type.uhtypeArticleen
dc.description.notes<p>Cited By :8</p>en
dc.source.abbreviationChiralityen
dc.contributor.orcidKapnissi‐Christodoulou, Constantina P. [0000-0003-3755-1052]
dc.gnosis.orcid0000-0003-3755-1052


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record