Show simple item record

dc.contributor.authorQuan, Kinen
dc.contributor.authorShipley, Rebecca J.en
dc.contributor.authorTanno, Ryutaroen
dc.contributor.authorMcPhillips, Graemeen
dc.contributor.authorVavourakis, Vasileiosen
dc.contributor.authorEdwards, Daviden
dc.contributor.authorJacob, Josephen
dc.contributor.authorHurst, John R.en
dc.contributor.authorHawkes, David J.en
dc.creatorQuan, Kinen
dc.creatorShipley, Rebecca J.en
dc.creatorTanno, Ryutaroen
dc.creatorMcPhillips, Graemeen
dc.creatorVavourakis, Vasileiosen
dc.creatorEdwards, Daviden
dc.creatorJacob, Josephen
dc.creatorHurst, John R.en
dc.creatorHawkes, David J.en
dc.date.accessioned2021-01-27T10:17:44Z
dc.date.available2021-01-27T10:17:44Z
dc.date.issued2018
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/63778
dc.description.abstractBronchiectasis is the permanent dilation of airways. Patients with the disease can suffer recurrent exacerbations, reducing their quality of life. The gold standard to diagnose and monitor bronchiectasis is accomplished by inspection of chest computed tomography (CT) scans. A clinician examines the broncho-arterial ratio to determine if an airway is brochiectatic. The visual analysis assumes the blood vessel diameter remains constant, although this assumption is disputed in the literature. We propose a simple measurement of tapering along the airways to diagnose and monitor bronchiectasis. To this end, we constructed a pipeline to measure the cross-sectional area along the airways at contiguous intervals, starting from the carina to the most distal point observable. Using a phantom with calibrated 3D printed structures, the precision and accuracy of our algorithm extends to the sub voxel level. The tapering measurement is robust to bifurcations along the airway and was applied to chest CT images acquired in clinical practice. The result is a statistical difference in tapering rate between airways with bronchiectasis and controls.en
dc.publisherInternational Society for Optics and Photonicsen
dc.sourceMedical Imaging 2018: Image Processingen
dc.source.urihttps://www.spiedigitallibrary.org/conference-proceedings-of-spie/10574/105742G/Tapering-analysis-of-airways-with-bronchiectasis/10.1117/12.2292306.short
dc.titleTapering analysis of airways with bronchiectasisen
dc.typeinfo:eu-repo/semantics/conferenceObject
dc.identifier.doi10.1117/12.2292306
dc.description.volume10574
dc.author.facultyΠολυτεχνική Σχολή / Faculty of Engineering
dc.author.departmentΤμήμα Μηχανικών Μηχανολογίας και Κατασκευαστικής / Department of Mechanical and Manufacturing Engineering
dc.type.uhtypeConference Objecten
dc.contributor.orcidVavourakis, Vasileios [0000-0002-4102-2084]
dc.gnosis.orcid0000-0002-4102-2084


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record