Show simple item record

dc.contributor.authorPetroudi, Stylianien
dc.contributor.authorLoizou, Christos P.en
dc.contributor.authorPantzaris, Marios C.en
dc.contributor.authorPattichis, Marios S.en
dc.contributor.authorPattichis, Constantinos S.en
dc.creatorPetroudi, Stylianien
dc.creatorLoizou, Christos P.en
dc.creatorPantzaris, Marios C.en
dc.creatorPattichis, Marios S.en
dc.creatorPattichis, Constantinos S.en
dc.date.accessioned2019-11-13T10:41:59Z
dc.date.available2019-11-13T10:41:59Z
dc.date.issued2011
dc.identifier.issn1557-170X
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/54835
dc.description.abstractThe thickness of the intima-media complex (IMC) of the common carotid artery (CCA) wall is important in the evaluation of the risk for the development of atherosclerosis. This paper presents a fully automated algorithm for the segmentation of the IMC. The segmentation of the IMC of the CCA wall is important for the evaluation of the intima media thickness (IMT) on B-mode ultrasound images. The presented algorithm is based on active contours and active contours without edges. It begins with image normalization, followed by speckle removal. The level set formulation of Chan and Vese using random initialization provides a segmentation of the CCA ultrasound (US) images into different distinct regions, one of which corresponds to the carotid wall region above the lumen whilst another corresponds to the carotid wall region below the lumen and includes the IMC. The results of the corresponding segmentation combined with anatomical information provide a very accurate outline of the lumen-intima boundary. This outline serves as an excellent initialization for segmentation of the IMC using parametric active contours. The method lends itself to the development of a fully automated method for the delineation of the IMC. The mean and standard deviation of the thickness of the automatically segmented regions are 0.65 mm +/-0.17 mm and the corresponding values for the ground truth IMT are 0.66 mm +/-0.18 mm. The Wilcoxon rank sum test shows no significant difference.en
dc.sourceConference proceedings : ...Annual International Conference of the IEEE Engineering in Medicine and Biology Society.IEEE Engineering in Medicine and Biology Society.Conferenceen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84861692205&partnerID=40&md5=9c48fa81a2a7cea26d219a2912a7817e
dc.subjectmethodologyen
dc.subjectarticleen
dc.subjectAlgorithmsen
dc.subjecthumanen
dc.subjectHumansen
dc.subjectalgorithmen
dc.subjectpathologyen
dc.subjectechographyen
dc.subjectimage processingen
dc.subjectTunica Intimaen
dc.subjectcommon carotid arteryen
dc.subjectautomationen
dc.subjectCarotid Artery, Commonen
dc.subjectImage Processing, Computer-Assisteden
dc.subjectintimaen
dc.subjecttunica mediaen
dc.titleA fully automated method using active contours for the evaluation of the intima-media thickness in carotid US images.en
dc.typeinfo:eu-repo/semantics/article
dc.description.volume2011
dc.description.startingpage8053
dc.description.endingpage8057
dc.author.faculty002 Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences
dc.author.departmentΤμήμα Πληροφορικής / Department of Computer Science
dc.type.uhtypeArticleen
dc.source.abbreviationConf Proc IEEE Eng Med Biol Socen
dc.contributor.orcidPattichis, Constantinos S. [0000-0003-1271-8151]
dc.contributor.orcidPattichis, Marios S. [0000-0002-1574-1827]
dc.contributor.orcidLoizou, Christos P. [0000-0003-1247-8573]
dc.contributor.orcidPantzaris, Marios C. [0000-0003-2937-384X]
dc.gnosis.orcid0000-0003-1271-8151
dc.gnosis.orcid0000-0002-1574-1827
dc.gnosis.orcid0000-0003-1247-8573
dc.gnosis.orcid0000-0003-2937-384X


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record