Show simple item record

dc.contributor.authorStatheropoulos, Miltiades K.en
dc.contributor.authorPallis, George C.en
dc.contributor.authorMikedi, Katerinaen
dc.contributor.authorGiannoukos, S.en
dc.contributor.authorAgapiou, Agapiosen
dc.contributor.authorPappa, Athina A.en
dc.contributor.authorCole, A.en
dc.contributor.authorVautz, W.en
dc.contributor.authorThomas, Charles Lawrence Paulen
dc.creatorStatheropoulos, Miltiades K.en
dc.creatorPallis, George C.en
dc.creatorMikedi, Katerinaen
dc.creatorGiannoukos, S.en
dc.creatorAgapiou, Agapiosen
dc.creatorPappa, Athina A.en
dc.creatorCole, A.en
dc.creatorVautz, W.en
dc.creatorThomas, Charles Lawrence Paulen
dc.date.accessioned2019-11-21T06:22:53Z
dc.date.available2019-11-21T06:22:53Z
dc.date.issued2014
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/56145
dc.description.abstractThe design, development, and validation of a dynamic vapor generator are presented. The generator simulates human scent (odor) emissions from trapped victims in the voids of collapsed buildings. The validation of the device was carried out using a reference detector: a quadrupole mass spectrometer equipped with a pulsed sampling (PS-MS) system. A series of experiments were conducted for evaluating the simulator's performance, defining types and weights of different factors, and proposing further optimization of the device. The developed device enabled the production of stable and transient odor profiles in a controllable and reproducible way (relative standard deviation, RSD < 11%) at ppbv to low ppmv concentrations and allowed emission durations up to 30 min. Moreover, the factors affecting its optimum performance (i.e., evaporation chamber temperature, air flow rate through the mixing chamber, air flow rate through the evaporation chamber, and type of compound) were evaluated through an analysis of variance (ANOVA) tool revealing the next steps toward optimizing the generator. The developed simulator, potentially, can also serve the need for calibrating and evaluating the performance of analytical devices (e.g., gas chromatographers, ion mobility spectrometers, mass spectrometers, sensors, e-noses) in the field. Furthermore, it can contribute in better training of urban search and rescue (USaR) canines. © 2014 American Chemical Society.en
dc.sourceAnalytical Chemistryen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84898885416&doi=10.1021%2fac404175e&partnerID=40&md5=1713715ceec922213c43d08541def8de
dc.subjectOptimizationen
dc.subjecthumanen
dc.subjectHumansen
dc.subjectstandarden
dc.subjectReproducibility of Resultsen
dc.subjectReference Standardsen
dc.subjectAnimalsen
dc.subjectanimalen
dc.subjectchemistryen
dc.subjectreproducibilityen
dc.subjectVaporsen
dc.subjectEvaporationen
dc.subjectFlow rateen
dc.subjectAiren
dc.subjectdogen
dc.subjectDogsen
dc.subjectodoren
dc.subjectOdorsen
dc.subjectrescue worken
dc.subjecturineen
dc.subjectanalysisen
dc.subjectCollapsed buildingsen
dc.subjectMass spectrometersen
dc.subjectAir Movementsen
dc.subjectAnalytic equipmenten
dc.subjectEvaporation chambersen
dc.subjectIon mobility spectrometersen
dc.subjectMixing chamberen
dc.subjectOdor controlen
dc.subjectOptimum performanceen
dc.subjectQuadrupole mass spectrometeren
dc.subjectRelative standard deviationsen
dc.subjectUrban search and rescueen
dc.subjectVapor generatoren
dc.titleDynamic vapor generator that simulates transient odor emissions of victims entrapped in the voids of collapsed buildingsen
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1021/ac404175e
dc.description.volume86
dc.description.issue8
dc.description.startingpage3887
dc.description.endingpage3894
dc.author.faculty002 Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences
dc.author.departmentΤμήμα Χημείας / Department of Chemistry
dc.type.uhtypeArticleen
dc.description.notes<p>Cited By :2</p>en
dc.source.abbreviationAnal.Chem.en
dc.contributor.orcidAgapiou, Agapios [0000-0001-8371-0910]
dc.contributor.orcidPallis, George C. [0000-0003-1815-5468]
dc.contributor.orcidStatheropoulos, Miltiades K. [0000-0002-0658-3863]
dc.gnosis.orcid0000-0001-8371-0910
dc.gnosis.orcid0000-0003-1815-5468
dc.gnosis.orcid0000-0002-0658-3863


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record