Show simple item record

dc.contributor.authorGriffin, Maura B.en
dc.contributor.authorKyriacou, Efthyvoulos C.en
dc.contributor.authorPattichis, Constantinos S.en
dc.contributor.authorBond, Dawnen
dc.contributor.authorKakkos, Stavros K.en
dc.contributor.authorSabetai, Michaelen
dc.contributor.authorGeroulakos, Georgeen
dc.contributor.authorGeorgiou, Nikien
dc.contributor.authorDoré, C. J.en
dc.contributor.authorNicolaïdes, Andrew N.en
dc.creatorGriffin, Maura B.en
dc.creatorKyriacou, Efthyvoulos C.en
dc.creatorPattichis, Constantinos S.en
dc.creatorBond, Dawnen
dc.creatorKakkos, Stavros K.en
dc.creatorSabetai, Michaelen
dc.creatorGeroulakos, Georgeen
dc.creatorGeorgiou, Nikien
dc.creatorDoré, C. J.en
dc.creatorNicolaïdes, Andrew N.en
dc.date.accessioned2019-11-13T10:40:18Z
dc.date.available2019-11-13T10:40:18Z
dc.date.issued2010
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/54051
dc.description.abstractObjectives: The aim was to determine the diagnostic value of a juxtaluminal black (hypoechoic) area without a visible echogenic cap (JBA) in ultrasonic images of internal carotid artery plaques. Methods: Ultrasonic images of plaques from 324 patients with asymptomatic (n = 139) and symptomatic (n = 185) internal carotid 50% to 99% stenosis in relation to the bulb (European Carotid Surgery Trial) referred for duplex scanning were studied. The JBA in mm2 and the gray-scale median (GSM) were obtained after image normalization. Cut-off points for GSM and JBA (combined highest sensitivity with highest specificity) were determined from receiver operator characteristic (ROC) curves. Results: JBA ≥ 8 mm2 was associated with a high prevalence of symptomatic plaques in all grades of stenosis. In a multiple logistic regression model, increasing stenosis (mild, moderate, severe), GSM ≤ 15 and JBA ≥ 8 mm2 were independent predictors of the presence of hemispheric symptoms. This model could identify a high-risk group of 188 plaques that contained 142 (77%) of the 185 symptomatic plaques (odds ratio [OR], 6.7en
dc.description.abstract95% confidence interval [CI], 4.08-10.91), (P < .001), (sensitivity: 77%en
dc.description.abstractspecificity 66%en
dc.description.abstractpositive predictive value 75%en
dc.description.abstractnegative predictive value 68%). Conclusions: The results of this study indicate the diagnostic value and for the first time suggest a cut-off point of 8 mm2 for JBA. This cut-off point needs to be validated in other groups and then applied to prospective studies of asymptomatic patients. © 2010 Society for Vascular Surgery.en
dc.sourceJournal of Vascular Surgeryen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-77953688134&doi=10.1016%2fj.jvs.2010.02.265&partnerID=40&md5=5fca673b799773e2a4530de18b407a24
dc.subjectarticleen
dc.subjecthumanen
dc.subjectHumansen
dc.subjectCross-Sectional Studiesen
dc.subjectmajor clinical studyen
dc.subjectPredictive Value of Testsen
dc.subjectpriority journalen
dc.subjectprospective studyen
dc.subjectOdds Ratioen
dc.subjectmultivariate logistic regression analysisen
dc.subjectLogistic Modelsen
dc.subjectRisk Assessmenten
dc.subjecthigh risk populationen
dc.subjectultrasounden
dc.subjectdiagnostic valueen
dc.subjectPilot Projectsen
dc.subjectsensitivity and specificityen
dc.subjectSeverity of Illness Indexen
dc.subjectpredictive validityen
dc.subjectreceiver operating characteristicen
dc.subjectcarotid artery obstructionen
dc.subjectCarotid Artery, Internalen
dc.subjectcarotid atherosclerosisen
dc.subjectCarotid Stenosisen
dc.subjectCerebrovascular Disordersen
dc.subjectDoppler echographyen
dc.subjectGray scale echographyen
dc.subjectinternal carotid arteryen
dc.subjectjuxtaluminal hypoechoic areaen
dc.subjectROC Curveen
dc.subjectUltrasonography, Doppler, Duplexen
dc.titleJuxtaluminal hypoechoic area in ultrasonic images of carotid plaques and hemispheric symptomsen
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1016/j.jvs.2010.02.265
dc.description.volume52
dc.description.issue1
dc.description.startingpage69
dc.description.endingpage76
dc.author.faculty002 Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences
dc.author.departmentΤμήμα Πληροφορικής / Department of Computer Science
dc.type.uhtypeArticleen
dc.description.notes<p>Cited By :32</p>en
dc.source.abbreviationJ.Vasc.Surg.en
dc.contributor.orcidPattichis, Constantinos S. [0000-0003-1271-8151]
dc.contributor.orcidKyriacou, Efthyvoulos C. [0000-0002-4589-519X]
dc.gnosis.orcid0000-0003-1271-8151
dc.gnosis.orcid0000-0002-4589-519X


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record