Show simple item record

dc.contributor.authorLoizou, Christos P.en
dc.contributor.authorPattichis, Constantinos S.en
dc.contributor.authorPantzaris, Marios C.en
dc.contributor.authorTyllis, Theodosis K.en
dc.contributor.authorNicolaïdes, Andrew N.en
dc.creatorLoizou, Christos P.en
dc.creatorPattichis, Constantinos S.en
dc.creatorPantzaris, Marios C.en
dc.creatorTyllis, Theodosis K.en
dc.creatorNicolaïdes, Andrew N.en
dc.date.accessioned2019-11-13T10:41:06Z
dc.date.available2019-11-13T10:41:06Z
dc.date.issued2007
dc.identifier.urihttp://gnosis.library.ucy.ac.cy/handle/7/54447
dc.description.abstractUltrasound measurements of the human carotid artery walls are conventionally obtained by manually tracing interfaces between tissue layers. In this study we present a snakes segmentation technique for detecting the intima-media layer of the far wall of the common carotid artery (CCA) in longitudinal ultrasound images, by applying snakes, after normalization, speckle reduction, and normalization and speckle reduction. The proposed technique utilizes an improved snake initialization method, and an improved validation of the segmentation method. We have tested and clinically validated the segmentation technique on 100 longitudinal ultrasound images of the carotid artery based on manual measurements by two vascular experts, and a set of different evaluation criteria based on statistical measures and univariate statistical analysis. The results showed that there was no significant difference between all the snakes segmentation measurements and the manual measurements. For the normalized despeckled images, better snakes segmentation results with an intra-observer error of 0.08, a coefficient of variation of 12.5%, best Bland-Altman plot with smaller differences between experts (0.01, 0.09 for Expert1 and Expert 2, respectively), and a Hausdorff distance of 5.2, were obtained. Therefore, the pre-processing of ultrasound images of the carotid artery with normalization and speckle reduction, followed by the snakes segmentation algorithm can be used successfully in the measurement of IMT complementing the manual measurements. The present results are an expansion of data published earlier as an extended abstract in IFMBE Proceedings (Loizou et al. IEEE Int X Mediterr Conf Medicon Med Biol Eng POS-03 499:1-4, 2004). © International Federation for Medical and Biological Engineering 2006.en
dc.sourceMedical and Biological Engineering and Computingen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-33846418345&doi=10.1007%2fs11517-006-0140-3&partnerID=40&md5=dbfd1c7d762e09e9a1bd7f9b122e680d
dc.subjectarticleen
dc.subjectStatistical methodsen
dc.subjectAlgorithmsen
dc.subjecthumanen
dc.subjectHumansen
dc.subjectadulten
dc.subjectageden
dc.subjectfemaleen
dc.subjectmajor clinical studyen
dc.subjectmaleen
dc.subjectCardiovascular Diseasesen
dc.subjectvalidation processen
dc.subjectAnimalsen
dc.subjectunivariate analysisen
dc.subjectimage analysisen
dc.subjectBiologyen
dc.subjectcomputer analysisen
dc.subjectechographyen
dc.subjectimage processingen
dc.subjectdiagnostic procedureen
dc.subjectcerebrovascular accidenten
dc.subjecttransient ischemic attacken
dc.subjectimage qualityen
dc.subjectmeasurement erroren
dc.subjectTissueen
dc.subjectUltrasound imagingen
dc.subjectatherosclerosisen
dc.subjectcommon carotid arteryen
dc.subjectBiomaterialsen
dc.subjectBiomedical engineeringen
dc.subjectModels, Cardiovascularen
dc.subjectCarotid Artery, Commonen
dc.subjectCarotid arteryen
dc.subjectImage segmentationen
dc.subjectimage enhancementen
dc.subjectImage Interpretation, Computer-Assisteden
dc.subjectartery intimaen
dc.subjectartery mediaen
dc.subjectSnakesen
dc.subjectartifact reductionen
dc.subjectCartoid arteryen
dc.subjectimage displayen
dc.subjectIntima media thicknessen
dc.subjectNormalizationen
dc.subjectSpeckle reduction filteringen
dc.subjectTunica Mediaen
dc.subjectUltrasonic measurementen
dc.titleSnakes based segmentation of the common carotid artery intima mediaen
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1007/s11517-006-0140-3
dc.description.volume45
dc.description.issue1
dc.description.startingpage35
dc.description.endingpage49
dc.author.faculty002 Σχολή Θετικών και Εφαρμοσμένων Επιστημών / Faculty of Pure and Applied Sciences
dc.author.departmentΤμήμα Πληροφορικής / Department of Computer Science
dc.type.uhtypeArticleen
dc.description.notes<p>Tradenames: HDI-3000, Advanced Technology, United Statesen
dc.description.notesManufacturers: Advanced Technology, United Statesen
dc.description.notesCited By :137</p>en
dc.source.abbreviationMed.Biol.Eng.Comput.en
dc.contributor.orcidPattichis, Constantinos S. [0000-0003-1271-8151]
dc.contributor.orcidLoizou, Christos P. [0000-0003-1247-8573]
dc.contributor.orcidPantzaris, Marios C. [0000-0003-2937-384X]
dc.gnosis.orcid0000-0003-1271-8151
dc.gnosis.orcid0000-0003-1247-8573
dc.gnosis.orcid0000-0003-2937-384X


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record